B Grade B

IBM Heron r3: Layer fidelity (error per layered gate)

3.08 × 10⁻³ error per layered gate

As stated in the source: “EPLG-100 = 0.00308 (x10^-3 in source)”

Caveats

Preprint, not peer reviewed. Benchmark implementations are Metriq's own (metriq-gym) and may differ from vendor definitions. EPLG is an error rate (lower is better), not a layer fidelity; chain selection method not read in full. Measurement window only (Nov 2025 to Feb 2026).

Set-up
ibm_boston. Layer-fidelity/EPLG on qubit chains of length 10, 20, 50, 100 where supported; value shown is chain length 100. Data captured November 2025 to February 2026.
Method
EPLG (error per layered gate, derived from layer fidelity) at chain length 100, metriq-gym implementation; closest ID is layer-fidelity
Compared only with
results in the group “eplg 100 metriq”
Measured
Not stated
Published
9 March 2026
Measured by
Unitary Foundation (Metriq project)
Independent of the maker
Yes
Peer-reviewed
No
Repeated by others
Not yet

Source

Metriq: A Collaborative Platform for Benchmarking Quantum Computers, arXiv. Preprint.

History

Spotted a mistake? Report an error, quoting r-000059.